Im Display des OpenStage HFA Telefons stehen manchmal Fehlercodes. Dieser Artikel listet die Fehlercodes übersichtlich auf.
In dieser Tabelle findest Du weitere Hinweise auf den angezeigten Fehler:
Error code | Error Condition | Error Cause |
---|---|---|
D02 | Unable to contact DHCP | |
H2 | Unable to register HFA main line | Logoff: Forced client logoff due to an incorrect PreSharedSecret |
H02 | Unable to register HFA main line | General Error |
H12 | Unable to register HFA main line | No IP address |
H22 | Unable to register HFA main line | No default route |
H32 | Unable to register HFA main line | No mask |
H42 | Unable to register HFA main line | No gateway IP address |
H52 | Unable to register HFA main line | No subscriber number |
H62 | Unable to register HFA main line | Tc-logon timeout |
Ha2 | Unable to register HFA main line | Logon: Rejected due to missing LIN |
HA2 | Unable to register HFA main line | Logon: Maintenance busy |
Hb2 | Unable to register HFA main line | Logon: Rejected due to invalid LIN |
HB2 | Unable to register HFA main line | Logon: No port available |
Hc2 | Unable to register HFA main line | Logon: Rejected due to mobile terminal blocked |
Hd2 | Unable to register HFA main line | Logon: Rejected due to incompatible security profile |
HD2 | Unable to register HFA main line | Logon: No port ext available |
He2 | Unable to register HFA main line | Logon: Rejected due to TCP usage while TLS is required |
HE2 | Unable to register HFA main line | Logon: Client not registered |
Hf2 | Unable to register HFA main line | Logon: Reject due to PBX version not sufficient |
HF2 | Unable to register HFA main line | Logon: Rejected due to Logoff |
HG2 | Unable to register HFA main line | Logon: Rejected due to Logoff progress |
HH2 | Unable to register HFA main line | Logon: Rejected due to Shutdown |
HI2 | Unable to register HFA main line | Logon: Rejected due to duplicate Logon |
HJ2 | Unable to register HFA main line | Logon: Rejected due to already logged on |
HK2 | Unable to register HFA main line | Logon: Rejected due to PIN not present |
HL2 | Unable to register HFA main line | Logon: Rejected due to password not present |
HM2 | Unable to register HFA main line | Logon: Rejected due to password not correct |
HN2 | Unable to register HFA main line | Logon: Rejected due to invalid license |
HQ2 | Unable to register HFA main line | Logoff: Normal Logoff |
HR2 | Unable to register HFA main line | Logoff: Client not logged on |
HS2 | Unable to register HFA main line | Logoff: Client logged off |
HT2 | Unable to register HFA main line | Logoff: Forced client logoff |
HU2 | Unable to register HFA main line | Logoff: Timeout expired |
HV2 | Unable to register HFA main line | Logoff: OMCaction |
HW2 | Unable to register HFA main line | Logoff: Hfa mobile user logged on |
HX2 | Unable to register HFA main line | Logoff: Switch back to central system |
HY2 | Unable to register HFA main line | Logoff: No bearer channel |
HZ2 | Unable to register HFA main line | Logoff: New logon requested from the server |
LI1 | Unable to use LAN connection | Network Configuration Error |
LP1 | Unable to use LAN connection | Physical connection error |
LX1 | Unable to use LAN connection | 802.1x errors |
TT2 | Unable to establish a TLS connection | No SNTP server |
NT | Limited service | SNTP server error |
Bitte beachte, dass der letzte Teil des Fehlercodes die Priorität angibt und diese wird auf die höchste Priorität der vorliegenden Fehler aktualisiert. Zum Beispiel: Wenn das LAN-Kabel ausgesteckt ist, zeigt das Telefon zunächst LP1 an. Nachdem die Verbindung zwischen Telefon und System abgebrochen ist, würde das Telefon normalerweise auch H02 als Registrierungsfehler anzeigen. Da aber LP1 einen Fehler der Priorität 1 anzeigt, wird die Priorität des H0-Fehlers von 2 auf 1 aktualisiert, so dass er als H01 angezeigt wird.
Hier sind noch weitere beliebte Beiträge:
- Unify IP Telefon updaten und flashen
- Factory Reset für Openscape Desk Phone CP und OpenStage
- DECT in der OpenScape Business konfigurieren
- Unify OpenScape CP und OpenStage IP Telefon Tastenkombinationen (für die Werkseinstellung und Neustart)
- Error Codes / Fehlercodes in Unify HFA IP Telefonen (OpenStage und OpenScape Desk Phone CP)
- Error Codes / Fehlercodes in Unify SIP Telefonen
- OpenScape Business Ports und Firewall-Regeln
- DLS IP Adresse in Unify IP Telefone konfigurieren